h e a l t h a n d r e l a x a t i o n f o r l i f e
DM INDUSTRIES, LTD.
2320 N.W. 147th Street Miami, Florida 33054
IMPORTANT SAFETY INSTRUCTIONS
READ ENTIRE MANUAL BEFORE INSTALLING SPA.
PLEASE SAVE THIS MANUAL.
U100 SERIES
OWNER’S MANUAL
Vedere la pagina 0
1 2 3 4 5 6 ... 34 35

Sommario

Pagina 1 - OWNER’S MANUAL

h e a l t h a n d r e l a x a t i o n f o r l i f eDM INDUSTRIES, LTD.2320 N.W. 147th Street Miami, Florida 33054IMPORTANT SAFETY INSTRUCTION

Pagina 2

PAGE 7GFCI MOUNTED IN PANEL AND DISCONNECT MOUNTED INSIDETO COMMON WALL WITH METAL STUDS OR WITH METAL MOUNTING BOX.GFCI IN PANEL WITH WEAK GROUND OR

Pagina 3 - TABLE OF CONTENTS

PAGE 8SEPARATE NEUTRAL & SOLID GROUNDCOMMON NEUTRAL GROUND BAR IN MAINGFCI IN PANEL WITH COMMON NEUTRAL BAR AND/OR ROMEXWITH UNDERSIZED WIRE USED

Pagina 4 - Eric Dormoy

PAGE 9INSTALLING THE SPA COVER1 . Position the cover squarely over the spa.2 . Position the locks for the tie-downs on the sides of the spa. You shoul

Pagina 5 - IMPORTANT SAFETY INSTRUCTIONS

PAGE 10OPERAT I NG INST RUCT IONSNOTE: For best results, read each stepcarefully and entirely before proceedingto the next.FILLING YOUR SPADo no

Pagina 6 - SAVE THESE INSTRUCTIONS

PAGE 11OPERAT I NG INST RUCT IONS3 . Press the “PROG” button to exit theprogramming mode.C. Setting Time and Filtration Hours1. Press and hold

Pagina 7

PAGE 12OPERAT I NG INST RUCT IONSF. LIGHT ButtonTurns the spa light ON and OFF. If left ON, the lightwill automatically go OFF after 9 hours.G. Auxili

Pagina 8 - CLEARANCES

PAGE 13JET OPERATIONYour spa is designed with a unique jet system to allow you to select a wide variety of massage patterns.The following is a descrip

Pagina 9 - TIGHTEN SECURELY!

PAGE 14D) DIRECTIONAL AND ROTATIONAL MASSAGE JETSWhen the pump is on and the 3-way diverter valve is directed to the bank of jets, the DirectionalQuad

Pagina 10

PAGE 15SAFETY FEATURESA. Freeze ProtectionIf the temperature in the spa plumbing falls below 50 degrees Fahrenheit (10 degrees celsius), thewater pump

Pagina 11

PAGE 16FILTER MAIN T E N A N C EYour Spa is designed with the most efficienttop loading filtration system in the industry.Filter maintenance is the

Pagina 12 - DANGER - RISK OF INJURY

OWNER’S RECORDDATE PURCHASED: _____________________________________DATE INSTALLED: _______________________________________DEALER: ____________________

Pagina 13 - TOP SIDE DIGI TAL CON T R OL

PAGE 17soft cloth and a mild soap solution (1teaspoon dish washing liquid with 2 gallons ofwater), scrub lightly in circular motion. Thenrins

Pagina 14

PAGE 18WATER QUALITY AND MAINTENANCEG E N E R AL GUID E L I NES FOR WAT E RQ UA L I T Y MAIN T E N A N C EMaintaining water quality within specific

Pagina 15

PAGE 19IMPORTANT WATER MAINTENANCE PROCEDURESDA I LY3 days a weekCheck water level. Keep water above bottom of skimmer doorand a minimum of 1” above h

Pagina 16 - JET OPERATION

PAGE 20Water treatment is an important factor in theenjoyment of your spa. Proper watersanitation is essential to your health as well aspermittin

Pagina 17

PAGE 214 . If the Alkalinity is not within the acceptablerange (80 to 120 ppm) it should beadjusted first. If it is low, raise the alkalinityby

Pagina 18 - SAFETY FEATURES

PAGE 22MONDAY1 . TEST THE WATER USING “3-WAY SPAWATER TEST STRIPS”.2 . Adjust pH and total alkalinity - Referto pH and total alkalinity on label of“P

Pagina 19 - S PA MAIN T E N A N C E

PAGE 23D O Add all chemicals slowly with the hydrojets operating in high speed.D O Use care when handling chemicals.D O Store granulated chlorine in

Pagina 20

PAGE 24SPA WAT E R TROUBL E S HOOT I NGSYMP TO MCloudy Wa te rWa ter OdorChlorine OdorMusty OdorFoaming Organic Buildup/Scum Ring AroundThe Tu bA l

Pagina 21 - WATER QUALITY AND MAINTENANCE

PAGE 25SPA WAT E R TROUBL E S HOOT I NGSYMP TOM Eye IrritationSkin Irritation/RashStains S c a l ePR O BA BLE CAUSELow pHInsufficient free available

Pagina 22

PAGE 26DIAGNOSTIC & TROUBLESHOOTINGResetting Your SpaLike your PC at home, your spa electronics could get corrupted by electrical surges and opera

Pagina 23 - WATER MAINTENANCE

GENERAL INFORMATION• Important Safety Instructions. . . . . . . . . 2-3• WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . 3• Manufacturer&a

Pagina 24 - B A LA N CING THE SPA WAT ER

PAGE 28MAINTENANCE LOGUse this section to keep a record of when you perform any maintenance on your spa._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Pagina 25 - B A LA N CING THE SPA WAT E R

MAINTENANCE LOG_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Pagina 26

PAGE 30MAINTENANCE LOG_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _

Pagina 27

Vita International extends this limited warranty solely tothe original Purchaser of any self-contained U 100 SpaS e r i e s installed within the Unite

Pagina 28

shall Vita International or any of its representativesbe held liable for injury to any person or damageto any propert y, however arising. Some states

Pagina 29 - Resetting Your Spa

Vita International, Ltd., 2320 Northwest 147th Street, Miami, Florida 330 54Phone: (305) 685-2063 or (305) 908-8187 • Toll Free: (877) 24 0 - 9 4 5 7

Pagina 30

PAGE 1Congratulations!Thank you for the purchase of your new Vita Spa. Your spa has been designed to be simple to own and operate. With a little care,

Pagina 31

PAGE 2IMPORTANT SAFETY INSTRUCTIONSWHEN INSTALLING AND USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONSSHOULD ALWAYS BE FOLLOWED, INCLUDING T

Pagina 32

PAGE 3E . Persons suffering from obesity or with a medicalhistory of heart disease, low or high bloodpressure, circulatory system problems, or

Pagina 33 - U100 SERIES

PAGE 4SITE SELECTIONYour spa is completely self-contained. It can beset up on a patio, deck, or indoor with specialconsideration. See diagram on page

Pagina 34

PAGE 5Spa L o c a t i o n123456CLEARANCESCHECK THE FOLLOWING AREAS PRIOR TO SPA DELIVERY1. STEPS - We suggest no more than six without a landing. 2. T

Pagina 35 - MIAMI FLORIDA

PAGE 61 . The spa must be permanently connected(hard wired) to the power supply. Noextension cords or plug-type connections areto be used

Commenti su questo manuale